100% Original Factory Pvc Flexible Duct - Eco-Smart HEPA Heat Energy Recovery Ventilators – Holtop
100% Original Factory Pvc Flexible Duct - Eco-Smart HEPA Heat Energy Recovery Ventilators – Holtop Detail:
Why Eco-Smart?
Modern buildings are being built tightly to improve energy efficiency. Eco-smart HEPA energy recovery ventilator (ERV) is ideal ventilation solution for energy efficient buildings to reduce ecological footprint and improve human health. The energy can be saved by using DC motors and improving energy efficiency with smart control system, to achieve eco friendly climatic experience.
Main Feature of Eco-Smart HEPA Energy Recovery Ventilators:
- Wide range air volume from 150m3/h to 6000m3/h, 10 speeds control
- High efficiency brush-less DC motor, ERP 2018 compliant
- High efficiency enthalpy heat recovery
- Auto bypass, intelligent controlled by outdoor temperature
- G3+F9 filter, efficiency over 96% to filter the particulate from 2.5µm to 10µm
- Intelligent control system, optional CO2 and humidity control function, external control and BMS control available
- Double filter alarm, timer alarm or different pressure gauge alarm available
- Specifications of Eco-Smart HEPA Energy Recovery Ventilators
Specification of Eco-Smart HEPA Energy Recovery Ventilators:
Model | Rated Airflow (m3/h) |
External Pressure (Pa) |
Enthalpy Efficiency (%) | Temperature Efficiency (%) |
Noise dB(A) |
Voltage (V) |
Power Input (W) |
N.W. (kg) |
|
Cooling | Heating | ||||||||
XHBQ-D1.5DMTHA | 150 | 70 | 60-65 | 63-70 | 75-80 | 31.5 | 220-240 | 38 | 25 |
XHBQ-D2.5DMTHA | 250 | 90 | 62-71 | 65-73 | 73-81 | 34.5 | 220-240 | 85 | 27 |
XHBQ-D3.5DMTHA | 350 | 140 | 62-70 | 65-73 | 74-82 | 37.5 | 220-240 | 107 | 33 |
XHBQ-D5DMTHA | 500 | 110 | 63-72 | 67-75 | 76-84 | 39 | 220-240 | 140 | 38 |
XHBQ-D6.5DMTHA | 650 | 100 | 60-67 | 65-71 | 74-82 | 41 | 220-240 | 160 | 62 |
XHBQ-D8DMTHA | 800 | 140 | 63-71 | 65-73 | 76-82 | 42 | 220-240 | 188 | 72 |
XHBQ-D10DMTHA | 1000 | 140 | 60-68 | 62-72 | 76-82 | 43 | 220-240 | 312 | 81 |
XHBQ-D13DMTHA | 1300 | 135 | 58-71 | 59-75 | 74-82 | 43 | 220-240 | 405 | 81 |
XHBQ-D15DMTHA | 1500 | 95 | 63-71 | 65-73 | 76-80 | 50 | 220-240 | 700 | 147 |
XHBQ-D20DMTHA | 2000 | 115 | 60-68 | 62-72 | 76-82 | 51.5 | 220-240 | 724 | 167 |
XHBQ-D26DMTHA | 2600 | 115 | 58-66 | 59-75 | 74-82 | 55 | 220-240 | 810 | 190 |
XHBQ-D40DMTHA | 4000 | 230 | 60-68 | 61-71 | 73-81 | 59 | 380-400 | 2140 | 335 |
XHBQ-D50DMTHA | 5000 | 260 | 60-68 | 61-71 | 73-81 | 68 | 380-400 | 2630 | 395 |
XHBQ-D60DMTHA | 6000 | 300 | 60-68 | 61-71 | 73-81 | 70 | 380-400 | 3030 | 557 |
Product detail pictures:
Related Product Guide:
New Mercedes-Benz CLA Spied & Teased Ahead Of 8 Jan 2019 Reveal | Whole House Air Exchanger
Comparing THT Heat Transfer Technology (OTCMKTS:THTI) and Paul Mueller (MUEL) | Silent Ventilation Fan
We pursue the management tenet of "Quality is remarkable, Company is supreme, Name is first", and will sincerely create and share success with all clientele for 100% Original Factory Pvc Flexible Duct - Eco-Smart HEPA Heat Energy Recovery Ventilators – Holtop, The product will supply to all over the world, such as: Sweden, Tajikistan, Bulgaria, During in 11 years, We've participated in more than 20 exhibitions, obtains the highest praise from each customer. Our company has been devoting that "customer first" and committed to helping customers expand their business, so that they become the Big Boss !
commercial heat recovery ventilator
Heat Recovery Ventilators
Heat Recovery Ventilator
Single Room Heat Recovery Ventilator
Hrv Heat Recovery Ventilator
By Lorraine from France - 2015.09.29 13:24
We have been looking for a professional and responsible supplier, and now we find it.
By Nancy from Cologne - 2016.01.28 19:59