Our firm has been concentrating on brand strategy. Customers' satisfaction is our best advertising. We also offer OEM provider for Dehumidifier Air Purifier, Plate Heat Exchanger Sizing, Ventilation Price, Welcome all prospects of residence and abroad to visit our organization, to forge a outstanding potential by our cooperation.
Best-Selling c Air Quality Monitor - Liquid Circulation Heat Exchangers – Holtop Detail:

Liquid Circulation Heat Exchanger 

Working Principle

Liquid circulation heat exchanger is liquid to air heat exchanger, heat exchangers installed in both fresh air side and exhaust air side, the pump between the 2 heat

exchangers make the liquid circulate then the heat in the liquid preheat or precool the fresh air. Normally the liquid is water but in order to decrease the freezing point,

moderate ethylene glycol will be added into the water according to reasonable percentage.

Features

(1) Fresh air and exhaust air heat exchanged by separated liquid pipes, zero cross contamination.Suitable for hospital, germfree lab and industries which discharge

poisonous and harmful gas.

(2) Stable and reliable operation, long service life

(3) Flexible connection between fresh air and exhaust air exchangers, easy installation which is convenient for old AHU improvement.

(4) Accessories like water pump, heat exchangers are conventional, easy and low maintanence costs.

(5) Wide range of application, various connection ways like one to one, one to many or many to many.

Specifications

(1) Liquid circulation heat exchanger is sensible heat exchanger, efficiency is between 55% to 60%.

(2) Suggested rows are 6 or 8, face velocity not over 2.8m/s

(3) The choice of circulating pump can refer to the fresh air and exhuast air pressure drop and the waterflow pressure drop.

(4) Air flow direction has significant effect on the heat recovery efficiency, influence rate up to 20%.

(5) Freezing point of the hybrid ethylene glycol and water should be 4 to 6 celsius lower than the local minimum winter outdoor temperature, percentage of hybridcan

be refered to the following table.

Freezing point -1.4 - 1.3 -5.4 -7.8 -10.7 -14.1 -17.9 -22.3
Weight percentage (%) 5 10 15 20 25 30 35 40
Volume percentage (% ) 4.4 8.9 13.6 18.1 22.9 27.7 32.6 37.5
5 6

Product detail pictures:

Best-Selling c Air Quality Monitor - Liquid Circulation Heat Exchangers – Holtop detail pictures

Best-Selling c Air Quality Monitor - Liquid Circulation Heat Exchangers – Holtop detail pictures


Related Product Guide:
Head to Head Analysis: ROTORK PLC/ADR (RTOXY) & UGI (UGI) | Air Ventilation System
Researcher says there’s a better way to ventilate homes in the North | Fresh Air Ventilation Systems

To be a result of ours specialty and service consciousness, our company has won a superb reputation between customers all around the environment for Best-Selling c Air Quality Monitor - Liquid Circulation Heat Exchangers – Holtop, The product will supply to all over the world, such as: Hanover, Lithuania, Curacao, With more than 9 years of experience and a professional team, we have exported our products to many countries and regions all over the world. We welcome customers, business associations and friends from all parts of the world to contact us and seek cooperation for mutual benefits.
Heat Recovery Ventilator
commercial heat recovery ventilator
Hrv Heat Recovery Ventilator
Ductless Heat Recovery Ventilator
Heat Recovery Ventilators
Single Room Heat Recovery Ventilator

This is a very professional wholesaler, we always come to their company for procurement, good quality and cheap.
5 Stars By Anna from Comoros - 2016.10.27 12:12
Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!
5 Stars By Nelly from Singapore - 2015.02.04 14:13

Related Products