The customer satisfaction is our primary target. We uphold a consistent level of professionalism, quality, credibility and service for Ventilation Vents, Fresh Air Ventilation, Hrv Vent, We would like to take this opportunity to establish long-term business relationships with clients from all over the world.
China Supplier Air Conditioning Vent Covers - Liquid Circulation Heat Exchangers – Holtop Detail:

Liquid Circulation Heat Exchanger 

Working Principle

Liquid circulation heat exchanger is liquid to air heat exchanger, heat exchangers installed in both fresh air side and exhaust air side, the pump between the 2 heat

exchangers make the liquid circulate then the heat in the liquid preheat or precool the fresh air. Normally the liquid is water but in order to decrease the freezing point,

moderate ethylene glycol will be added into the water according to reasonable percentage.

Features

(1) Fresh air and exhaust air heat exchanged by separated liquid pipes, zero cross contamination.Suitable for hospital, germfree lab and industries which discharge

poisonous and harmful gas.

(2) Stable and reliable operation, long service life

(3) Flexible connection between fresh air and exhaust air exchangers, easy installation which is convenient for old AHU improvement.

(4) Accessories like water pump, heat exchangers are conventional, easy and low maintanence costs.

(5) Wide range of application, various connection ways like one to one, one to many or many to many.

Specifications

(1) Liquid circulation heat exchanger is sensible heat exchanger, efficiency is between 55% to 60%.

(2) Suggested rows are 6 or 8, face velocity not over 2.8m/s

(3) The choice of circulating pump can refer to the fresh air and exhuast air pressure drop and the waterflow pressure drop.

(4) Air flow direction has significant effect on the heat recovery efficiency, influence rate up to 20%.

(5) Freezing point of the hybrid ethylene glycol and water should be 4 to 6 celsius lower than the local minimum winter outdoor temperature, percentage of hybridcan

be refered to the following table.

Freezing point -1.4 - 1.3 -5.4 -7.8 -10.7 -14.1 -17.9 -22.3
Weight percentage (%) 5 10 15 20 25 30 35 40
Volume percentage (% ) 4.4 8.9 13.6 18.1 22.9 27.7 32.6 37.5
5 6

Product detail pictures:

China Supplier Air Conditioning Vent Covers - Liquid Circulation Heat Exchangers – Holtop detail pictures

China Supplier Air Conditioning Vent Covers - Liquid Circulation Heat Exchangers – Holtop detail pictures


Related Product Guide:
Recreational Cancer: Blame Lifestyle and Luck, Not Trace Chemicals | Air Ventilation System
Samsung launches Fresh Access ventilation product | Silent Ventilation Fan

The purchaser fulfillment is our primary focus on. We uphold a consistent level of professionalism, high quality, credibility and service for China Supplier Air Conditioning Vent Covers - Liquid Circulation Heat Exchangers – Holtop, The product will supply to all over the world, such as: Romania, Berlin, Cape Town, Our aim is to help customers realize their goals. We are making great efforts to achieve this win-win situation and sincerely welcome you to join us. In a word, when you choose us, you choose a perfect life. Welcome to visit our factory and welcome your order! For further inquiries, please do not hesitate to contact us.
Single Room Heat Recovery Ventilator
commercial heat recovery ventilator
Heat Recovery Ventilator
Heat Recovery Ventilators
Hrv Heat Recovery Ventilator
Ductless Heat Recovery Ventilator

A good manufacturers, we have cooperated twice, good quality and good service attitude.
5 Stars By David from Seychelles - 2016.01.11 17:15
We feel easy to cooperate with this company, the supplier is very responsible, thanks.There will be more in-depth cooperation.
5 Stars By Jane from Yemen - 2015.07.26 16:51

Related Products