We usually continually offer you the most conscientious consumer services, along with the widest variety of designs and styles with finest materials. These initiatives include the availability of customized designs with speed and dispatch for Air Ventilation, Dehumidifiers For Sale, Mvhr System, The main goal of our company would be to live a satisfactory memory to all of the shoppers, and establish a long term company romantic relationship with customers and users all around the entire world.
Excellent quality Dehumidification System - Heat Wheels – Holtop Detail:

Rotary heat exchanger (wheel) is mainly used in building ventilation or in the air supply/discharge system of air conditioning equipment. The wheel transfers the energy (cold or heat) contained in exhaust air to the fresh air supplied to indoor. It’s one important equipment and key technology in the field of construction energy-saving.
Rotary heat exchanger is composed of heat wheel, case, drive system and sealing parts. The heat wheel rotates powered by the drive system. When outdoor air passes through half of the wheel, return air passes through reversely the rest half of the wheel. In this process, about 70% to 90% heat contained in the return air can be recovered to supply air to indoor.

Working Principle

Rotary heat exchanger is composed of alveolate
heat wheel, case, drive system and sealing parts.
The exhaust and outdoor air pass through half of the
wheel separately, when the wheel rotates, the heat
and moisture are exchanged between the exhaust and
outdoor air. The energy recovery efficiency is up to
70% to 90%

rotary heat exchanger

Sensible Wheel MaterialsThe sensible heat wheel is made by aluminum foils of 0.05mm thickness.
Wheel Construction
The wheel of the rotary heat exchanger is made of alternating layers of
flat and corrugated aluminum foil to form the alveolate shape.
Various height of corrugation is available.
Flat surface ensures minimum leakage.
Interior spokes are used to mechanically bond the rotor’s laminations.
These are threaded at the hub and welded at the periphery. 

rotary heat exchanger 4

 

rotary heat exchanger 5
Applications
Rotary heat exchanger can built in air handling unit (AHU) as a main part of the heat recovery section. Usually side
panel of the exchanger casing is unnecessary, except that bypass has been set in AHU.
 rotary heat exchanger application
It can also be installed in the ducts of ventilation system as a main part of the heat recovery section, connected by
flange. In this case, side panel of the exchanger is necessary to prevent leakage.  rotary heat exchanger application 2
Note: casing type and segment quantity should depend on the application spaces as well as transportation capability and conditions at installation. Over segmentation will increase the assembly work, and overlarge size will cause diffculties in transportation.
Application conditions:
- Ambient temperature: -40-70°C
- Max face velocity: 5.5m/s
- Max pressure on casing: 2000Pa

Product detail pictures:

Excellent quality Dehumidification System - Heat Wheels – Holtop detail pictures


Related Product Guide:
Heat Exchangers – Global Strategic Business Report 2018: Focus on Chemicals, Oil & Gas, Industrial HVAC and Refrigeration, Food and Beverage, Power Generation Industries | Fresh Air Ventilation Systems
A systems approach to hygiene in food processing environments | Whole House Air Exchanger

Attaining consumer satisfaction is our company's purpose without end. We will make wonderful endeavours to produce new and top-quality merchandise, satisfy your exclusive requirements and supply you with pre-sale, on-sale and after-sale services for Excellent quality Dehumidification System - Heat Wheels – Holtop, The product will supply to all over the world, such as: Johor, Australia, Mauritius, If you are for any reason unsure which product to select, do not hesitate to contact us and we will be delighted to advise and assist you. This way we will be providing you with all the knowledge needed to make the best choice. Our company strictly follows "Survive by good quality, Develop by keeping good credit. " operation policy. Welcome all the clients old and new to visit our company and talk about the business. We are looking for more and more customers to create the glorious future.
Heat Recovery Ventilators
commercial heat recovery ventilator
Hrv Heat Recovery Ventilator
Heat Recovery Ventilator
Single Room Heat Recovery Ventilator
Ductless Heat Recovery Ventilator

Although we are a small company, we are also respected. Reliable quality, sincere service and good credit, we are honored to be able to work with you!
5 Stars By Elsie from France - 2016.01.11 17:15
The supplier abide the theory of "quality the basic, trust the first and management the advanced" so that they can ensure a reliable product quality and stable customers.
5 Stars By Anna from Guatemala - 2016.08.18 18:38

Related Products