Main Feature of Commercial High Efficiency TP Series Heat Energy Recovery Ventilators ERVs
- Wide range of airflow, suitable for more application
- Higher heat exchange efficiency up to 80%
- Perfect silence design
- Air filtration and purification
- By-pass function
- Easy installation to ceiling
- High air-proof feature and easy maintenance
- Double filters
Specifications of Commercial High Efficiency TP Series Heat Recovery Ventilators ERVs
Model | Airflow(m3/h) | External pressure(Pa) |
Enthalpy Efficiency (%) |
Temperature efficiency (%) | Noise dB dB(A) | Voltage (V) | Current(A) | Input Power (W) | Net Weight (Kg) | ||||||||||||||||||
Cooling | Heating | ||||||||||||||||||||||||||
L | M | H | L | M | H | L | M | H | L | M | H | L | M | H | L | M | H | ||||||||||
XBQ-D1.5TP | 115 | 150 | 150 | 34 | 58 | 75 | 67 | 63 | 63 | 74 | 70 | 70 | 77 | 75 | 75 | 25 | 30 | 31.5 | 220 | 0.5 | 105 | 25 | |||||
XBQ-D2.5TP | 165 | 250 | 250 | 30 | 70 | 85 | 67 | 63 | 63 | 73 | 70 | 70 | 77 | 75 | 75 | 26 | 34 | 34.5 | 220 | 0.56 | 117 | 29 | |||||
XBQ-D3.5TP | 270 | 350 | 350 | 36 | 60 | 90 | 67 | 66 | 66 | 72 | 69 | 69 | 77 | 75 | 75 | 29 | 36.5 | 37.5 | 220 | 0.72 | 150 | 37 | |||||
XBQ-D5TP | 360 | 500 | 500 | 30 | 60 | 100 | 68 | 62 | 62 | 72 | 67 | 67 | 78 | 75 | 75 | 33 | 37 | 39 | 220 | 0.96 | 200 | 43 | |||||
XBQ-D6.5TP | 515 | 650 | 650 | 25 | 40 | 70 | 64 | 65 | 62 | 70 | 68 | 68 | 77 | 75 | 75 | 34 | 38 | 39.5 | 220 | 1.4 | 295 | 64 | |||||
XBQ-D8TP | 625 | 800 | 800 | 60 | 98 | 120 | 68 | 65 | 65 | 74 | 71 | 71 | 77 | 75 | 75 | 36 | 40 | 42 | 220 | 1.7 | 355 | 71 | |||||
XBQ-D10TP | 780 | 1000 | 1000 | 25 | 35 | 85 | 68 | 65 | 65 | 74 | 71 | 71 | 77 | 75 | 75 | 35 | 41 | 43 | 220 | 2.1 | 440 | 83 | |||||
XBQ-D15TP | 1250 | 1500 | 1500 | 20 | 45 | 75 | 68 | 65 | 65 | 74 | 71 | 71 | 77 | 75 | 75 | 44 | 47 | 50 | 220 | 3.4 | 710 | 165 | |||||
XBQ-D20TP | 1700 | 2000 | 2000 | 20 | 25 | 60 | 68 | 65 | 65 | 74 | 71 | 71 | 77 | 75 | 75 | 46.5 | 49 | 51.5 | 220 | 4.2 | 880 | 189 |
Product detail pictures:
Related Product Guide:
Aftercoolers Market Growth Analysis, Share, Demand by Regions, Types and Analysis of Key Players- Research Forecasts to 2023 | Fresh Air Ventilation Systems
Global Energy Recovery Ventilator (ERV) Market Analysis 2013-2017 & Forecast 2018-2023 By Product Type, Capacity (CFM) Output, Installation Type, End Use Application & Region – ResearchAndMarkets.com – Press Release | Silent Ventilation Fan
We strive for excellence, service the customers", hopes to become the best cooperation team and dominator enterprise for personnel, suppliers and customers, realizes value share and continuous promotion for Factory For vents \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\”non-insulated\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\” \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\”air Duct\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\” - Commercial High Efficiency TP Series Energy Recovery Ventilators – Holtop, The product will supply to all over the world, such as: Nepal, Romania, Japan, With the goal of "zero defect". To care for the environment, and social returns, care employee social responsibility as own duty. We welcome friends from all over the world to visit and guide us so that we can achieve the win-win goal together.
Ductless Heat Recovery Ventilator
Heat Recovery Ventilator
Single Room Heat Recovery Ventilator
Heat Recovery Ventilators
Hrv Heat Recovery Ventilator
By Modesty from Sri Lanka - 2016.11.01 17:04
Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!
By Karen from Malta - 2016.12.02 14:11