Factory Free sample Electric Louvered Fan Industrial - Sensible Plate Heat Exchanger – Holtop
Factory Free sample Electric Louvered Fan Industrial - Sensible Plate Heat Exchanger – Holtop Detail:
in Features
- Sensible heat recovery
- Total separation of fresh air & exhaust air streams
- Heat recovery efficiency up to 80%
- 2-side press shaping
- Double folded edge
- Completely joint sealing.
- Resistance of pressure difference up to 2500Pa
- Under pressure of 700Pa, air leakage less than 0.6%
Material type
B series (standard type)
Heat exchanger is made of pure aluminum foils, with galvanized end cover and aluminium alloy wrap angle. Max. air temperature 100℃, it is suitable for most of the occasion.
F series ( Anti-corrosion type)
Heat exchanger is made of pure aluminum foils cover by special anti-corrosion material, with galvanized end cover and aluminium alloy wrap angle., it is suitable for the corrosive gas occasion.
G series (high temperature type)
Heat exchanger is made of pure aluminum foils, with galvanized end cover and aluminium alloy wrap angle. Sealing material is special and allow the Max. air temperature to be 200℃, it is suitable for special high temperature occasion.
Aluminum foils thickness range from 0.12 to 0.18mm because of the different specification heat exchanger.
Heat exchanger size and air volume
Remarks:① Length is customized, but should be within the specified range.
② Size C is for reference, size can be slightly increased according to heat exchanger length. |
Specifications
Model | A (mm) | B (mm) | C (mm) | Length per piece (L) | Optional spacing (mm) | Remarks |
HBS-ZF250/250 | 250 | 250 | 356 | <=400 | 4.0 |
One module |
HBS-ZF300/300 | 300 | 300 | 427 | <=400 | 4.0 | |
HBS-ZF300/300 | 300 | 300 | 427 | <=500 | 5.0 | |
HBS-ZF350/350 | 350 | 350 | 498 | <=400 | 4.0 | |
HBS-ZF350/350 | 350 | 350 | 498 | <=500 | 5.0 | |
HBS-ZF350/350 | 350 | 350 | 498 | <=550 | 6.0 | |
HBS-ZF400/400 | 400 | 400 | 568 | <=400 | 4.0 | |
HBS-ZF400/400 | 400 | 400 | 568 | <=500 | 5.0 | |
HBS-ZF400/400 | 400 | 400 | 568 | <=550 | 6.0 | |
HBS-ZF500/500 | 500 | 500 | 710 | <=550 | 6.0, 8.0, 10.0 | |
HBS-ZF600/600 | 600 | 600 | 851 | <=550 | 6.0, 8.0, 10.0 | |
HBS-ZF700/700 | 700 | 700 | 993 | <=550 | 8.0, 10.0 | |
HBS-ZF800/800 | 800 | 800 | 1134 | <=550 | 8.0, 10.0 | |
HBS-ZF1000/1000 | 1000 | 1000 | 1417 | <=500 | 6.0, 8.0, 10.0 | Four modules combined |
HBS-ZF1200/1200 | 1200 | 1200 | 1702 | <=500 | 6.0, 8.0, 10.0 | |
HBS-ZF1400/1400 | 1400 | 1400 | 1985 | <=500 | 8.0, 10.0 | |
HBS-ZF1600/1600 | 1600 | 1600 | 2265 | <=500 | 8.0, 10.0 |
Product detail pictures:

Related Product Guide:
Utilizing VRF and DOAS for High-Performance Building Applications | 2018-09-17 | Silent Ventilation Fan
When to Inspect and Clean Your Heating, Ventilating and Air Conditioning System
We always believe that one's character decides products' quality, the details decides products' high-quality ,together with the REALISTIC,EFFICIENT AND INNOVATIVE crew spirit for Factory Free sample Electric Louvered Fan Industrial - Sensible Plate Heat Exchanger – Holtop, The product will supply to all over the world, such as: Dubai, Naples, New Zealand, we've got all day online sales to make sure the pre-sale and after-sale service in time. With all these supports, we can serve every customer with quality product and timely shipping with highly responsibility. Being a young growing company, we might not the best, but we are trying our best to be your good partner.
Single Room Heat Recovery Ventilator
commercial heat recovery ventilator
Hrv Heat Recovery Ventilator
Heat Recovery Ventilators
Heat Recovery Ventilator

Staff is skilled, well-equipped, process is specification, products meet the requirements and delivery is guaranteed, a best partner!