We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of Heat Exchange Ventilation System, Enthalpy Wheel, Air To Air Heat Exchanger, We have been wanting ahead to setting up cooperative associations along with you. Make sure you contact us for more data.
High reputation Turbo Exhaust Fan - Liquid Circulation Heat Exchangers – Holtop Detail:

Liquid Circulation Heat Exchanger

Working Principle

Liquid circulation heat exchanger is liquid to air heat exchanger, heat exchangers installed in both fresh air side and exhaust air side, the pump between the 2 heat

exchangers make the liquid circulate then the heat in the liquid preheat or precool the fresh air. Normally the liquid is water but in order to decrease the freezing point,

moderate ethylene glycol will be added into the water according to reasonable percentage.

Features

(1) Fresh air and exhaust air heat exchanged by separated liquid pipes, zero cross contamination.Suitable for hospital, germfree lab and industries which discharge

poisonous and harmful gas.

(2) Stable and reliable operation, long service life

(3) Flexible connection between fresh air and exhaust air exchangers, easy installation which is convenient for old AHU improvement.

(4) Accessories like water pump, heat exchangers are conventional, easy and low maintanence costs.

(5) Wide range of application, various connection ways like one to one, one to many or many to many.

Specifications

(1) Liquid circulation heat exchanger is sensible heat exchanger, efficiency is between 55% to 60%.

(2) Suggested rows are 6 or 8, face velocity not over 2.8m/s

(3) The choice of circulating pump can refer to the fresh air and exhuast air pressure drop and the waterflow pressure drop.

(4) Air flow direction has significant effect on the heat recovery efficiency, influence rate up to 20%.

(5) Freezing point of the hybrid ethylene glycol and water should be 4 to 6 celsius lower than the local minimum winter outdoor temperature, percentage of hybridcan

be refered to the following table.

Freezing point -1.4 - 1.3 -5.4 -7.8 -10.7 -14.1 -17.9 -22.3
Weight percentage (%) 5 10 15 20 25 30 35 40
Volume percentage (% ) 4.4 8.9 13.6 18.1 22.9 27.7 32.6 37.5
5 6

Product detail pictures:

High reputation Turbo Exhaust Fan - Liquid Circulation Heat Exchangers – Holtop detail pictures

High reputation Turbo Exhaust Fan - Liquid Circulation Heat Exchangers – Holtop detail pictures


Related Product Guide:
The 3 myths of PTAC units | Silent Ventilation Fan
Tesla Model 3 Cabin Air Filter Put To Real-World Test | Air Heat Exchangers

With our outstanding administration, powerful technical capability and strict top quality handle procedure, we go on to provide our purchasers with reliable good quality, reasonable selling prices and excellent services. We goal at becoming certainly one of your most responsible partners and earning your gratification for High reputation Turbo Exhaust Fan - Liquid Circulation Heat Exchangers – Holtop, The product will supply to all over the world, such as: Suriname, Nepal, Luxembourg, Many products fully conform to the most rigorous of international guidelines and with our first-rate delivery service you will have them delivered at any time and in any place. And because Kayo deals in the entire spectrum of protective equipment, our customers don't need to waste time shopping around.
commercial heat recovery ventilator
Heat Recovery Ventilators
Single Room Heat Recovery Ventilator
Ductless Heat Recovery Ventilator
Hrv Heat Recovery Ventilator
Heat Recovery Ventilator

Speaking of this cooperation with the Chinese manufacturer, I just want to say"well dodne", we are very satisfied.
5 Stars By Georgia from Greece - 2016.05.02 18:28
We are a small company that has just started, but we get the company leader's attention and gave us a lot of help. Hope we can make progress together!
5 Stars By Kay from Philadelphia - 2016.06.22 12:49

Related Products