So as to provide you with ease and enlarge our business, we even have inspectors in QC Crew and guarantee you our best company and solution for Whole House Ventilation, Horizontal Air Handler, Erv System, Any interest, make sure you really feel free to get hold of us. We're searching forward to forming prosperous enterprise interactions with new purchasers across the earth within the near upcoming.
Low MOQ for Heating And Ventilation Companies - Liquid Circulation Heat Exchangers – Holtop Detail:

Liquid Circulation Heat Exchanger 

Working Principle

Liquid circulation heat exchanger is liquid to air heat exchanger, heat exchangers installed in both fresh air side and exhaust air side, the pump between the 2 heat

exchangers make the liquid circulate then the heat in the liquid preheat or precool the fresh air. Normally the liquid is water but in order to decrease the freezing point,

moderate ethylene glycol will be added into the water according to reasonable percentage.

Features

(1) Fresh air and exhaust air heat exchanged by separated liquid pipes, zero cross contamination.Suitable for hospital, germfree lab and industries which discharge

poisonous and harmful gas.

(2) Stable and reliable operation, long service life

(3) Flexible connection between fresh air and exhaust air exchangers, easy installation which is convenient for old AHU improvement.

(4) Accessories like water pump, heat exchangers are conventional, easy and low maintanence costs.

(5) Wide range of application, various connection ways like one to one, one to many or many to many.

Specifications

(1) Liquid circulation heat exchanger is sensible heat exchanger, efficiency is between 55% to 60%.

(2) Suggested rows are 6 or 8, face velocity not over 2.8m/s

(3) The choice of circulating pump can refer to the fresh air and exhuast air pressure drop and the waterflow pressure drop.

(4) Air flow direction has significant effect on the heat recovery efficiency, influence rate up to 20%.

(5) Freezing point of the hybrid ethylene glycol and water should be 4 to 6 celsius lower than the local minimum winter outdoor temperature, percentage of hybridcan

be refered to the following table.

Freezing point -1.4 - 1.3 -5.4 -7.8 -10.7 -14.1 -17.9 -22.3
Weight percentage (%) 5 10 15 20 25 30 35 40
Volume percentage (% ) 4.4 8.9 13.6 18.1 22.9 27.7 32.6 37.5
5 6

Product detail pictures:

Low MOQ for Heating And Ventilation Companies - Liquid Circulation Heat Exchangers – Holtop detail pictures

Low MOQ for Heating And Ventilation Companies - Liquid Circulation Heat Exchangers – Holtop detail pictures


Related Product Guide:
Cincinnati Streetcar: Mold found in ventilation system | Fresh Air Ventilation Systems
This is Jaguar’s first real attempt to take on Tesla | Fresh Air Ventilation Systems

Every single member from our large efficiency revenue team values customers' wants and company communication for Low MOQ for Heating And Ventilation Companies - Liquid Circulation Heat Exchangers – Holtop, The product will supply to all over the world, such as: Las Vegas, Slovakia, Malta, Each year, many of our customers would visit our company and achieve great business advancements working with us. We sincerely welcome you to visit us at any time and together we will prevail to a greater success in the hair industry.
commercial heat recovery ventilator
Heat Recovery Ventilators
Ductless Heat Recovery Ventilator
Heat Recovery Ventilator
Hrv Heat Recovery Ventilator
Single Room Heat Recovery Ventilator

In our cooperated wholesalers, this company has the best quality and reasonable price, they are our first choice.
5 Stars By Christine from Congo - 2016.11.01 17:04
A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
5 Stars By Arabela from Cancun - 2015.12.10 19:03

Related Products