- Sensible heat recovery
- Total separation of fresh air & exhaust air streams
- Heat recovery efficiency up to 80%
- 2-side press shaping
- Double folded edge
- Completely joint sealing.
- Resistance of pressure difference up to 2500Pa
- Under pressure of 700Pa, air leakage less than 0.6%
Material type
B series (standard type)
Heat exchanger is made of pure aluminum foils, with galvanized end cover and aluminium alloy wrap angle. Max. air temperature 100℃, it is suitable for most of the occasion.
F series ( Anti-corrosion type)
Heat exchanger is made of pure aluminum foils cover by special anti-corrosion material, with galvanized end cover and aluminium alloy wrap angle., it is suitable for the corrosive gas occasion.
G series (high temperature type)
Heat exchanger is made of pure aluminum foils, with galvanized end cover and aluminium alloy wrap angle. Sealing material is special and allow the Max. air temperature to be 200℃, it is suitable for special high temperature occasion.
Aluminum foils thickness range from 0.12 to 0.18mm because of the different specification heat exchanger.
Heat exchanger size and air volume
Remarks:① Length is customized, but should be within the specified range.
② Size C is for reference, size can be slightly increased according to heat exchanger length. |
Specifications
Model | A (mm) | B (mm) | C (mm) | Length per piece (L) | Optional spacing (mm) | Remarks |
HBS-ZF250/250 | 250 | 250 | 356 | <=400 | 4.0 |
One module |
HBS-ZF300/300 | 300 | 300 | 427 | <=400 | 4.0 | |
HBS-ZF300/300 | 300 | 300 | 427 | <=500 | 5.0 | |
HBS-ZF350/350 | 350 | 350 | 498 | <=400 | 4.0 | |
HBS-ZF350/350 | 350 | 350 | 498 | <=500 | 5.0 | |
HBS-ZF350/350 | 350 | 350 | 498 | <=550 | 6.0 | |
HBS-ZF400/400 | 400 | 400 | 568 | <=400 | 4.0 | |
HBS-ZF400/400 | 400 | 400 | 568 | <=500 | 5.0 | |
HBS-ZF400/400 | 400 | 400 | 568 | <=550 | 6.0 | |
HBS-ZF500/500 | 500 | 500 | 710 | <=550 | 6.0, 8.0, 10.0 | |
HBS-ZF600/600 | 600 | 600 | 851 | <=550 | 6.0, 8.0, 10.0 | |
HBS-ZF700/700 | 700 | 700 | 993 | <=550 | 8.0, 10.0 | |
HBS-ZF800/800 | 800 | 800 | 1134 | <=550 | 8.0, 10.0 | |
HBS-ZF1000/1000 | 1000 | 1000 | 1417 | <=500 | 6.0, 8.0, 10.0 | Four modules combined |
HBS-ZF1200/1200 | 1200 | 1200 | 1702 | <=500 | 6.0, 8.0, 10.0 | |
HBS-ZF1400/1400 | 1400 | 1400 | 1985 | <=500 | 8.0, 10.0 | |
HBS-ZF1600/1600 | 1600 | 1600 | 2265 | <=500 | 8.0, 10.0 |
Product detail pictures:

Related Product Guide:
Electronic Cabinet Cooling System Consumption Market Dynamics and Manufacturers Profiles to 2023 | Fresh Air Ventilation Systems
Suspects Break into Sacramento Liquor Store Through Its Ventilation System | Silent Ventilation Fan
With a positive and progressive attitude to customer's curiosity, our organization repeatedly improves our products top quality to meet the wants of consumers and further focuses on safety, reliability, environmental necessities, and innovation of Low MOQ for Heating Vents - Sensible Plate Heat Exchanger – Holtop, The product will supply to all over the world, such as: Lebanon, Bolivia, Somalia, Our products have won an excellent reputation at each of the related nations. Because the establishment of our firm. we've insisted on our production procedure innovation together with the most recent modern day managing method, attracting a sizable quantity of talents within this industry. We regard the solution good quality as our most vital essence character.
Single Room Heat Recovery Ventilator
Ductless Heat Recovery Ventilator
Heat Recovery Ventilator
Heat Recovery Ventilators
commercial heat recovery ventilator

Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.