OEM China Blowing Ventilation Duct - Total Heat Exchanger – Holtop

Short Description:


Product Detail

Tags

Feedback (2)

We aim to find out quality disfigurement from the production and supply the best service to domestic and overseas customers wholeheartedly for Sa11694 Air Handler, Heat Recovery Ventilator, Central Air Conditioning Prices, We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
OEM China Blowing Ventilation Duct - Total Heat Exchanger – Holtop Detail:

Working Principle of Holtop Crossflow Plate Fin Total Heat Exchangers (E.R. Paper for enthalpy exchange core)

The flat plates and the corrugated plates form channels for fresh or exhaust air stream.

When the two air steams passing through the exchanger crossly with temperature difference, the energy is recovered.

 5

Main features

1. Made of E.R. paper, which is featured by high moisture permeability, good air tightness, excellent tear resistance, and aging resistance. 
2. Structured with flat plates and corrugated plates.
3. Two air streams flow crossly.
4. Suitable for room ventilation and industrial ventilation system. 
5. Heat recovery efficiency up to 70%

5

Gas molecules type Carbon dioxide (CO2) Ammonia (NH3) Methane (CH4) Vapor(H2O) The clearance of fiber
Diameters(nm) 0.324 0.308 0.324 0.288 0.3(for reference)

Application

Used in comfortable air conditioning ventilation system and technical air conditioning ventilation system. Supply air and ex- haust air totally separated, heat recovery in winter and cold re- covery in Summer

Specifications

Model A (mm) L (mm) C (mm) Optional corrugation height (mm) Remarks
HBT-W168/168 168 ≤500 240 2.0, 2.5      

 

 

 

 

One module

HBT -W202/202 202 ≤500 288 2.0, 2.5
HBT -W222/222 222 ≤500 317 2.0, 2.5
HBT-W250/250 250 ≤700 356 2.0, 2.5, 3.5
HBT-W300/300 300 ≤700 427 2.0, 2.5, 3.5
HBT -W350/350 350 ≤700 498 2.5, 3.5
HBT -W372/372 372 ≤700 529 2.5, 3.5
HBT -W400/400 400 ≤700 568 3.5
HBT -W472/472 472 ≤550 670 3.5
HBT -W500/500 500 ≤550 710 3.5
HBT -W552/552 552 ≤550 783 3.5
HBT -W600/600 600 ≤550 851 3.5
HBT -W652/652 652 ≤550 925 3.5
HBT -W700/700 700 ≤550 993 3.5    Multi-modulecombined
HBT -W800/800 800 ≤550 1134 3.5
HBT-W1000/1000 1000 ≤450 1417 3.5
HBT-W1200/1200 1200 ≤450 1702 3.5
HBT -W1400/1400 1400 ≤450 1985 3.5
HBT -W1600/1600 1600 ≤450 2265 3.5

 


Product detail pictures:

OEM China Blowing Ventilation Duct - Total Heat Exchanger – Holtop detail pictures


Related Product Guide:
Modine granted new hot gas reheat system patent | 2018-12-26 | Whole House Air Exchanger
Lenovo to Debut ‘Neptune’ Cooling Technologies at ISC | Air Heat Exchangers

owing to excellent assistance, a variety of top of the range items, aggressive costs and efficient delivery, we take pleasure in a very good standing amongst our shoppers. We've been an energetic corporation with wide market for OEM China Blowing Ventilation Duct - Total Heat Exchanger – Holtop, The product will supply to all over the world, such as: Finland, Iceland, US, With well educated, innovative and energetic staff, we are responsible for all elements of research, design, manufacture, sale and distribution. By studying and developing new techniques, we are not only following but also leading fashion industry. We listen attentively to the feedback from our customers and provide instant replies. You will instantly feel our professional and attentive service.
Hrv Heat Recovery Ventilator
Heat Recovery Ventilator
Ductless Heat Recovery Ventilator
Heat Recovery Ventilators
Single Room Heat Recovery Ventilator
commercial heat recovery ventilator

The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!
5 Stars By Maggie from Costa Rica - 2016.08.18 18:38
This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
5 Stars By Jamie from Sri Lanka - 2016.02.18 15:54

Related Products