OEM/ODM China Duct Fan Ventilation - Liquid Circulation Heat Exchangers – Holtop
OEM/ODM China Duct Fan Ventilation - Liquid Circulation Heat Exchangers – Holtop Detail:
Liquid Circulation Heat Exchanger
Working Principle
Liquid circulation heat exchanger is liquid to air heat exchanger, heat exchangers installed in both fresh air side and exhaust air side, the pump between the 2 heat
exchangers make the liquid circulate then the heat in the liquid preheat or precool the fresh air. Normally the liquid is water but in order to decrease the freezing point,
moderate ethylene glycol will be added into the water according to reasonable percentage.
Features
(1) Fresh air and exhaust air heat exchanged by separated liquid pipes, zero cross contamination.Suitable for hospital, germfree lab and industries which discharge
poisonous and harmful gas.
(2) Stable and reliable operation, long service life
(3) Flexible connection between fresh air and exhaust air exchangers, easy installation which is convenient for old AHU improvement.
(4) Accessories like water pump, heat exchangers are conventional, easy and low maintanence costs.
(5) Wide range of application, various connection ways like one to one, one to many or many to many.
Specifications
(1) Liquid circulation heat exchanger is sensible heat exchanger, efficiency is between 55% to 60%.
(2) Suggested rows are 6 or 8, face velocity not over 2.8m/s
(3) The choice of circulating pump can refer to the fresh air and exhuast air pressure drop and the waterflow pressure drop.
(4) Air flow direction has significant effect on the heat recovery efficiency, influence rate up to 20%.
(5) Freezing point of the hybrid ethylene glycol and water should be 4 to 6 celsius lower than the local minimum winter outdoor temperature, percentage of hybridcan
be refered to the following table.
Freezing point | -1.4 | - 1.3 | -5.4 | -7.8 | -10.7 | -14.1 | -17.9 | -22.3 |
Weight percentage (%) | 5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 |
Volume percentage (% ) | 4.4 | 8.9 | 13.6 | 18.1 | 22.9 | 27.7 | 32.6 | 37.5 |
Product detail pictures:


Related Product Guide:
Climate change: Earth-air heat exchanger best to protect animals in livestock buildings | Fresh Air Ventilation Systems
Head to Head Analysis: ROTORK PLC/ADR (RTOXY) & UGI (UGI) | Air Ventilation System
All we do is often involved with our tenet " Purchaser to start with, Rely on initially, devoting over the food stuff packaging and environmental defense for OEM/ODM China Duct Fan Ventilation - Liquid Circulation Heat Exchangers – Holtop, The product will supply to all over the world, such as: Lahore, Sevilla, Egypt, In order to meet our market demands, we have paied more attention to the quality of our products and services. Now we can meet customers' special requirements for special designs. We persistently develop our enterprise spirit "quality lives the enterprise, credit assures cooperation and keep the motto in our minds: customers first.
Single Room Heat Recovery Ventilator
commercial heat recovery ventilator
Heat Recovery Ventilators
Ductless Heat Recovery Ventilator
Hrv Heat Recovery Ventilator

The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!