Working Principle
Liquid circulation heat exchanger is liquid to air heat exchanger, heat exchangers installed in both fresh air side and exhaust air side, the pump between the 2 heat
exchangers make the liquid circulate then the heat in the liquid preheat or precool the fresh air. Normally the liquid is water but in order to decrease the freezing point,
moderate ethylene glycol will be added into the water according to reasonable percentage.
Features
(1) Fresh air and exhaust air heat exchanged by separated liquid pipes, zero cross contamination.Suitable for hospital, germfree lab and industries which discharge
poisonous and harmful gas.
(2) Stable and reliable operation, long service life
(3) Flexible connection between fresh air and exhaust air exchangers, easy installation which is convenient for old AHU improvement.
(4) Accessories like water pump, heat exchangers are conventional, easy and low maintanence costs.
(5) Wide range of application, various connection ways like one to one, one to many or many to many.
Specifications
(1) Liquid circulation heat exchanger is sensible heat exchanger, efficiency is between 55% to 60%.
(2) Suggested rows are 6 or 8, face velocity not over 2.8m/s
(3) The choice of circulating pump can refer to the fresh air and exhuast air pressure drop and the waterflow pressure drop.
(4) Air flow direction has significant effect on the heat recovery efficiency, influence rate up to 20%.
(5) Freezing point of the hybrid ethylene glycol and water should be 4 to 6 celsius lower than the local minimum winter outdoor temperature, percentage of hybridcan
be refered to the following table.
Freezing point | -1.4 | - 1.3 | -5.4 | -7.8 | -10.7 | -14.1 | -17.9 | -22.3 |
Weight percentage (%) | 5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 |
Volume percentage (% ) | 4.4 | 8.9 | 13.6 | 18.1 | 22.9 | 27.7 | 32.6 | 37.5 |
Product detail pictures:


Related Product Guide:
The Differences Between Air-To-Air and Air-To-Water Intercoolers | Whole House Air Exchanger
Challenges of Proper Air Ventilation | Air Heat Exchangers
Bear "Customer first, Quality first" in mind, we work closely with our customers and provide them with efficient and professional services for PriceList for Air Dehumidifier - Liquid Circulation Heat Exchangers – Holtop, The product will supply to all over the world, such as: Lyon, Belarus, Stuttgart, We set a strict quality control system. We have return and exchange policy, and you can exchange within 7 days after receive the wigs if it is in new station and we service repairing free for our products. Please feel free to contact us for further information if you have any questions. We are glad to work for every client.
Heat Recovery Ventilator
commercial heat recovery ventilator
Ductless Heat Recovery Ventilator
Heat Recovery Ventilators
Single Room Heat Recovery Ventilator

We are long-term partners, there is no disappointment every time, we hope to maintain this friendship later!