Liquid Circulation Heat Exchanger
Working Principle
Liquid circulation heat exchanger is liquid to air heat exchanger, heat exchangers installed in both fresh air side and exhaust air side, the pump between the 2 heat
exchangers make the liquid circulate then the heat in the liquid preheat or precool the fresh air. Normally the liquid is water but in order to decrease the freezing point,
moderate ethylene glycol will be added into the water according to reasonable percentage.
Features
(1) Fresh air and exhaust air heat exchanged by separated liquid pipes, zero cross contamination.Suitable for hospital, germfree lab and industries which discharge
poisonous and harmful gas.
(2) Stable and reliable operation, long service life
(3) Flexible connection between fresh air and exhaust air exchangers, easy installation which is convenient for old AHU improvement.
(4) Accessories like water pump, heat exchangers are conventional, easy and low maintanence costs.
(5) Wide range of application, various connection ways like one to one, one to many or many to many.
Specifications
(1) Liquid circulation heat exchanger is sensible heat exchanger, efficiency is between 55% to 60%.
(2) Suggested rows are 6 or 8, face velocity not over 2.8m/s
(3) The choice of circulating pump can refer to the fresh air and exhuast air pressure drop and the waterflow pressure drop.
(4) Air flow direction has significant effect on the heat recovery efficiency, influence rate up to 20%.
(5) Freezing point of the hybrid ethylene glycol and water should be 4 to 6 celsius lower than the local minimum winter outdoor temperature, percentage of hybridcan
be refered to the following table.
Freezing point | -1.4 | - 1.3 | -5.4 | -7.8 | -10.7 | -14.1 | -17.9 | -22.3 |
Weight percentage (%) | 5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 |
Volume percentage (% ) | 4.4 | 8.9 | 13.6 | 18.1 | 22.9 | 27.7 | 32.6 | 37.5 |
Product detail pictures:
Related Product Guide:
Considerations for Air Ventilation Systems in Hospitals
Recreational Cancer: Blame Lifestyle and Luck, Not Trace Chemicals | Air Ventilation System
The organization upholds the philosophy of "Be No.1 in good quality, be rooted on credit history and trustworthiness for growth", will keep on to provide previous and new customers from home and overseas whole-heatedly for PriceList for Kitchen Exhaust Fan - Liquid Circulation Heat Exchangers – Holtop, The product will supply to all over the world, such as: Macedonia, Norway, Jersey, After 13 years of researching and developing products, our brand can represent wide range of products with outstanding quality in world market. We have completed big contracts from many countries such as Germany, Israel, Ukraine, United Kingdom, Italy, Argentina, France, Brazil, and so on. You probably feel secure and satisfy when copperate with us.
commercial heat recovery ventilator
Heat Recovery Ventilators
Single Room Heat Recovery Ventilator
Hrv Heat Recovery Ventilator
Ductless Heat Recovery Ventilator
By Merry from Burundi - 2015.06.03 10:17
This enterprise in the industry is strong and competitive, advancing with the times and develop sustainable, we are very pleased to have a opportunity to cooperate!
By Rachel from Nigeria - 2015.08.12 12:27