Short Lead Time for Fireplace Fin Heat Exchanger - Total Heat Exchanger – Holtop
Short Lead Time for Fireplace Fin Heat Exchanger - Total Heat Exchanger – Holtop Detail:
Working Principle of Holtop Crossflow Plate Fin Total Heat Exchangers (E.R. Paper for enthalpy exchange core)
The flat plates and the corrugated plates form channels for fresh or exhaust air stream.
When the two air steams passing through the exchanger crossly with temperature difference, the energy is recovered. |
|
Main features
1. Made of E.R. paper, which is featured by high moisture permeability, good air tightness, excellent tear resistance, and aging resistance.
2. Structured with flat plates and corrugated plates.
3. Two air streams flow crossly.
4. Suitable for room ventilation and industrial ventilation system.
5. Heat recovery efficiency up to 70%
Gas molecules type | Carbon dioxide (CO2) | Ammonia (NH3) | Methane (CH4) | Vapor(H2O) | The clearance of fiber |
Diameters(nm) | 0.324 | 0.308 | 0.324 | 0.288 | 0.3(for reference) |
Application
Used in comfortable air conditioning ventilation system and technical air conditioning ventilation system. Supply air and ex- haust air totally separated, heat recovery in winter and cold re- covery in Summer
Specifications
Model | A (mm) | L (mm) | C (mm) | Optional corrugation height (mm) | Remarks |
HBT-W168/168 | 168 | ≤500 | 240 | 2.0, 2.5 |
One module |
HBT -W202/202 | 202 | ≤500 | 288 | 2.0, 2.5 | |
HBT -W222/222 | 222 | ≤500 | 317 | 2.0, 2.5 | |
HBT-W250/250 | 250 | ≤700 | 356 | 2.0, 2.5, 3.5 | |
HBT-W300/300 | 300 | ≤700 | 427 | 2.0, 2.5, 3.5 | |
HBT -W350/350 | 350 | ≤700 | 498 | 2.5, 3.5 | |
HBT -W372/372 | 372 | ≤700 | 529 | 2.5, 3.5 | |
HBT -W400/400 | 400 | ≤700 | 568 | 3.5 | |
HBT -W472/472 | 472 | ≤550 | 670 | 3.5 | |
HBT -W500/500 | 500 | ≤550 | 710 | 3.5 | |
HBT -W552/552 | 552 | ≤550 | 783 | 3.5 | |
HBT -W600/600 | 600 | ≤550 | 851 | 3.5 | |
HBT -W652/652 | 652 | ≤550 | 925 | 3.5 | |
HBT -W700/700 | 700 | ≤550 | 993 | 3.5 | Multi-modulecombined |
HBT -W800/800 | 800 | ≤550 | 1134 | 3.5 | |
HBT-W1000/1000 | 1000 | ≤450 | 1417 | 3.5 | |
HBT-W1200/1200 | 1200 | ≤450 | 1702 | 3.5 | |
HBT -W1400/1400 | 1400 | ≤450 | 1985 | 3.5 | |
HBT -W1600/1600 | 1600 | ≤450 | 2265 | 3.5 |
Product detail pictures:

Related Product Guide:
Considerations for Air Ventilation Systems in Hospitals
Heat Exchanger Market Outlook, Opportunities and Forecasts Report 2018 | Silent Ventilation Fan
We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate in our success for Short Lead Time for Fireplace Fin Heat Exchanger - Total Heat Exchanger – Holtop, The product will supply to all over the world, such as: New York, Moldova, Nigeria, Our company will continue to serve customers with best quality, competitive price and timely delivery & the best payment term! We sincerely welcome friends from all over the world to visit& cooperate with us and enlarge our business. If you are interested in our products, please do not hesitate to contact us, we will be happy to provide you with further information!
Hrv Heat Recovery Ventilator
Ductless Heat Recovery Ventilator
Single Room Heat Recovery Ventilator
Heat Recovery Ventilators
commercial heat recovery ventilator

The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!