Trending Products Best Fresh Indoor Air Single Way Blower Fresh Air Filtration Systems
Main Feature
The single-way fresh air filtration system supplies outdoor fresh air to room with high purification. It's equipped with double filters with PM2.5 filtration rate over 95%. The airflow ranges from 150m3/h to 15000m3/h for different applications. It can be used to work together with Holtop energy recovery ventilator for better air purification either used independently for air purification in air conditioning system.
It has the optional functions of indoor circulation. In the situation when it's not suitable to introduce outdoor fresh air, it can bypass the air in the room for indoor air purification only.
One product can solve all your air quality problem: fresh air, air purification and cleanness with much lower costs. Please don't hesitate to contact our sales team for more information.
Different installation way for reference:
1)Single-way Fresh Air Filtration System Installation
2)Single-way Fresh Air Filtration + Energy Recovery Ventilation System Installation
Specification:
Model |
Airflow(m3/h) |
External pressure(Pa) |
Input power(W) |
Current (A) |
Noise dB(A) |
Power supply |
Weight (kg) |
||||||||||
L |
M |
H |
L |
M |
H |
L |
M |
H |
L |
M |
H |
L |
M |
H |
|||
DX1.5B2 |
120 |
150 |
150 |
55 |
68 |
88 |
45 |
53 |
56 |
0.25 |
0.3 |
0.31 |
25 |
31 |
32 |
220V/50Hz |
14 |
DX2.5B2 |
210 |
250 |
250 |
45 |
55 |
65 |
59 |
82 |
90 |
0.3 |
0.41 |
0.45 |
30 |
33 |
34 |
220V/50Hz |
14.3 |
DX3.5B2 |
260 |
350 |
350 |
53 |
70 |
80 |
113 |
172 |
180 |
0.58 |
0.83 |
0.85 |
32 |
36 |
37 |
220V/50Hz |
18.5 |
KJ-06C |
350 |
550 |
600 |
25 |
20 |
25 |
90 |
103 |
115 |
0.45 |
0.52 |
0.56 |
32 |
37 |
39 |
220V/50Hz |
25 |
KJ-08C |
700 |
800 |
800 |
130 |
150 |
170 |
140 |
200 |
238 |
0.7 |
1 |
1.2 |
35 |
39 |
41 |
220V/50Hz |
25 |
KJ-10C |
900 |
1000 |
1000 |
80 |
90 |
120 |
190 |
235 |
280 |
1 |
1.2 |
1.4 |
35 |
40 |
43 |
220V/50Hz |
25 |
KJ-13C |
1000 |
1300 |
1300 |
40 |
60 |
90 |
320 |
398 |
500 |
1.7 |
2.1 |
2.5 |
39 |
43 |
45 |
220V/50Hz |
25 |
Model |
Airflow(m3/h) | External Pressure(Pa) | Input Power (W) | Current (A) | Noise dB(A) | Power supply | Weight(Kg) | |||||
L |
H |
L |
H |
L |
H | L |
H |
L |
H |
|||
DX1.5B4 |
100 |
150 |
55 |
80 |
40 |
57 | 0.25 |
0.31 |
25 |
32 |
220V/50Hz |
8 |
DX2.5B4 |
150 |
250 |
60 |
100 |
68 |
85 | 0.3 |
0.45 |
30 |
34 |
220V/50Hz |
8 |
DX3.5B4 |
200 |
350 |
100 |
120 |
108 |
154 | 0.58 |
0.85 |
32 |
37 |
220V/50Hz |
10.5 |
Model |
Speed |
Airflow(m3/h) |
External Pressure (Pa) |
Input Power (W) |
Noise dB(A) |
Power supply | Weight (Kg) |
DX1.5DCB4 |
5 |
150 |
80 |
41 |
32 |
220V/50Hz |
9 |
4 |
120 |
64 |
29 |
||||
3 |
90 |
48 |
27 |
||||
2 |
60 |
32 |
25 |
||||
1 |
30 |
16 |
23 |
||||
DX2.5DCB4 |
5 |
250 |
100 |
60 |
34 |
220V/50Hz |
9 |
4 |
200 |
80 |
31 |
||||
3 |
150 |
60 |
29 |
||||
2 |
100 |
40 |
27 |
||||
1 |
50 |
20 |
25 |
||||
DX3.5DCB4 |
5 |
350 |
120 |
114 |
37 |
220V/50Hz |
9.5 |
4 |
280 |
96 |
33 |
||||
3 |
210 |
72 |
31 |
||||
2 |
140 |
48 |
29 |
||||
1 |
70 |
24 |
27 |
Single Room Heat Recovery Ventilator
Heat Recovery Ventilator
Heat Recovery Ventilators
Hrv Heat Recovery Ventilator
commercial heat recovery ventilator