Well-designed Vent Fan For Air Duct - Total Heat Exchanger – Holtop
Well-designed Vent Fan For Air Duct - Total Heat Exchanger – Holtop Detail:
Working Principle of Holtop Crossflow Plate Fin Total Heat Exchangers (E.R. Paper for enthalpy exchange core)
The flat plates and the corrugated plates form channels for fresh or exhaust air stream.
When the two air steams passing through the exchanger crossly with temperature difference, the energy is recovered. |
Main features
1. Made of E.R. paper, which is featured by high moisture permeability, good air tightness, excellent tear resistance, and aging resistance.
2. Structured with flat plates and corrugated plates.
3. Two air streams flow crossly.
4. Suitable for room ventilation and industrial ventilation system.
5. Heat recovery efficiency up to 70%
Gas molecules type | Carbon dioxide (CO2) | Ammonia (NH3) | Methane (CH4) | Vapor(H2O) | The clearance of fiber |
Diameters(nm) | 0.324 | 0.308 | 0.324 | 0.288 | 0.3(for reference) |
Application
Used in comfortable air conditioning ventilation system and technical air conditioning ventilation system. Supply air and ex- haust air totally separated, heat recovery in winter and cold re- covery in Summer
Specifications
Model | A (mm) | L (mm) | C (mm) | Optional corrugation height (mm) | Remarks |
HBT-W168/168 | 168 | ≤500 | 240 | 2.0, 2.5 |
One module |
HBT -W202/202 | 202 | ≤500 | 288 | 2.0, 2.5 | |
HBT -W222/222 | 222 | ≤500 | 317 | 2.0, 2.5 | |
HBT-W250/250 | 250 | ≤700 | 356 | 2.0, 2.5, 3.5 | |
HBT-W300/300 | 300 | ≤700 | 427 | 2.0, 2.5, 3.5 | |
HBT -W350/350 | 350 | ≤700 | 498 | 2.5, 3.5 | |
HBT -W372/372 | 372 | ≤700 | 529 | 2.5, 3.5 | |
HBT -W400/400 | 400 | ≤700 | 568 | 3.5 | |
HBT -W472/472 | 472 | ≤550 | 670 | 3.5 | |
HBT -W500/500 | 500 | ≤550 | 710 | 3.5 | |
HBT -W552/552 | 552 | ≤550 | 783 | 3.5 | |
HBT -W600/600 | 600 | ≤550 | 851 | 3.5 | |
HBT -W652/652 | 652 | ≤550 | 925 | 3.5 | |
HBT -W700/700 | 700 | ≤550 | 993 | 3.5 | Multi-modulecombined |
HBT -W800/800 | 800 | ≤550 | 1134 | 3.5 | |
HBT-W1000/1000 | 1000 | ≤450 | 1417 | 3.5 | |
HBT-W1200/1200 | 1200 | ≤450 | 1702 | 3.5 | |
HBT -W1400/1400 | 1400 | ≤450 | 1985 | 3.5 | |
HBT -W1600/1600 | 1600 | ≤450 | 2265 | 3.5 |
Product detail pictures:
Related Product Guide:
Are annual furnace inspections really necessary? | Air Heat Exchangers
Zacks Investment Research Downgrades Aggreko (ARGKF) to Hold | Air Ventilation System
Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" as well as theory of "quality the basic, have faith in the initial and administration the advanced" for Well-designed Vent Fan For Air Duct - Total Heat Exchanger – Holtop, The product will supply to all over the world, such as: Austria, Kyrgyzstan, Ukraine, We believe that good business relationships will lead to mutual benefits and improvement for both parties. We now have established long-term and successful cooperative relationships with many customers through their confidence in our customized services and integrity in doing business. We also enjoy a high reputation through our good performance. Better performance will be expected as our principle of integrity. Devotion and Steadiness will remain as ever.
Single Room Heat Recovery Ventilator
Ductless Heat Recovery Ventilator
Heat Recovery Ventilators
commercial heat recovery ventilator
Hrv Heat Recovery Ventilator
By Lindsay from Belgium - 2015.06.03 10:17
The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
By Arlene from UK - 2016.07.07 13:00