Well-designed Vent Fan For Air Duct - Total Heat Exchanger – Holtop

Short Description:


Product Detail

Tags

Feedback (2)

It adheres on the tenet "Honest, industrious, enterprising, innovative" to acquire new solutions regularly. It regards shoppers, success as its very own success. Let us establish prosperous future hand in hand for Air Vents For Homes, Room Ventilation, Energy Recovery Ventilator, We welcome clients, enterprise associations and friends from all components from the earth to make contact with us and find cooperation for mutual positive aspects.
Well-designed Vent Fan For Air Duct - Total Heat Exchanger – Holtop Detail:

Working Principle of Holtop Crossflow Plate Fin Total Heat Exchangers (E.R. Paper for enthalpy exchange core)

The flat plates and the corrugated plates form channels for fresh or exhaust air stream.

When the two air steams passing through the exchanger crossly with temperature difference, the energy is recovered.

 5

Main features

1. Made of E.R. paper, which is featured by high moisture permeability, good air tightness, excellent tear resistance, and aging resistance. 
2. Structured with flat plates and corrugated plates.
3. Two air streams flow crossly.
4. Suitable for room ventilation and industrial ventilation system. 
5. Heat recovery efficiency up to 70%

5

Gas molecules type Carbon dioxide (CO2) Ammonia (NH3) Methane (CH4) Vapor(H2O) The clearance of fiber
Diameters(nm) 0.324 0.308 0.324 0.288 0.3(for reference)

Application

Used in comfortable air conditioning ventilation system and technical air conditioning ventilation system. Supply air and ex- haust air totally separated, heat recovery in winter and cold re- covery in Summer

Specifications

Model A (mm) L (mm) C (mm) Optional corrugation height (mm) Remarks
HBT-W168/168 168 ≤500 240 2.0, 2.5      

 

 

 

 

One module

HBT -W202/202 202 ≤500 288 2.0, 2.5
HBT -W222/222 222 ≤500 317 2.0, 2.5
HBT-W250/250 250 ≤700 356 2.0, 2.5, 3.5
HBT-W300/300 300 ≤700 427 2.0, 2.5, 3.5
HBT -W350/350 350 ≤700 498 2.5, 3.5
HBT -W372/372 372 ≤700 529 2.5, 3.5
HBT -W400/400 400 ≤700 568 3.5
HBT -W472/472 472 ≤550 670 3.5
HBT -W500/500 500 ≤550 710 3.5
HBT -W552/552 552 ≤550 783 3.5
HBT -W600/600 600 ≤550 851 3.5
HBT -W652/652 652 ≤550 925 3.5
HBT -W700/700 700 ≤550 993 3.5    Multi-modulecombined
HBT -W800/800 800 ≤550 1134 3.5
HBT-W1000/1000 1000 ≤450 1417 3.5
HBT-W1200/1200 1200 ≤450 1702 3.5
HBT -W1400/1400 1400 ≤450 1985 3.5
HBT -W1600/1600 1600 ≤450 2265 3.5

 


Product detail pictures:

Well-designed Vent Fan For Air Duct - Total Heat Exchanger – Holtop detail pictures


Related Product Guide:
A systems approach to hygiene in food processing environments | Whole House Air Exchanger
Are annual furnace inspections really necessary? | Air Heat Exchangers

With advanced technologies and facilities, strict quality control, reasonable price, superior service and close co-operation with customers, we are devoted to providing the best value for our customers for Well-designed Vent Fan For Air Duct - Total Heat Exchanger – Holtop, The product will supply to all over the world, such as: Moscow, Houston, Moscow, We hope we can establish long-term cooperation with all of the customers. And hope we can improve competitiveness and achieve the win-win situation together with the customers. We sincerely welcome the customers from all over the world to contact us for anything you need!
Hrv Heat Recovery Ventilator
Single Room Heat Recovery Ventilator
Heat Recovery Ventilator
Ductless Heat Recovery Ventilator
Heat Recovery Ventilators
commercial heat recovery ventilator

Reasonable price, good attitude of consultation, finally we achieve a win-win situation,a happy cooperation!
5 Stars By Albert from Kuwait - 2016.06.16 18:23
With a positive attitude of "regard the market, regard the custom, regard the science", the company works actively to do research and development. Hope we have a future business relationships and achieving mutual success.
5 Stars By Megan from Dominica - 2015.12.28 15:18

Related Products